CERP Quality Assurance Systems Requirements (QASR)

This Quality Assurance Systems Requirements (QASR) manual lays out the protocols and procedures for environmental data gathering activities for the implementation of CERP. It is the foundation of the CERP quality assurance and quality control (QA/QC) program and will be periodically updated and refined in an effort to strengthen the QA/QC program for CERP. All agencies that will provide data during the implementation of CERP will be required to adhere to this manual. Implementation oversight of the QASR is the responsibility of the CERP QA Oversight Team (QAOT) and the key agencies QA/QC representatives or their designees, in coordination with CERP program and project managers.

Download the Final QASR Documents from 19 Mar 2009

Please note Chapter 8 is still draft and being revised.

Main Body:

  • Chapter 1
    Introduction (27 kb, PDF)
  • Chapter 2
    Administrative Procedures (77 kb, PDF)
  • Chapter 3 (updated 22 May 2009)
    Water Quality Sampling Procedures (116 kb, PDF)
  • Chapter 4
    Chemical Analysis and Laboratory Procedures (22 kb, PDF)
  • Chapter 5 (updated 22 May 2009)
    Verification and Validation of Chemistry Data (129 kb, PDF)
  • Chapter 6 (updated 7 Dec 2010)
    Hydrometeorologic and Hydraulic Monitoring (119 kb, PDF)
  • Chapter 7
    Soil and Sediment Characterization and Sampling Procedures (178 kb, PDF)
  • Chapter 8 (Please note: this chapter is currently being revised and will be available for review in the future)
    Biological Monitoring and Assessment Procedures (3.1 mb, PDF)
  • Chapter 9
    Remote Sensing Procedures (679 kb, PDF)
  • Chapter 10 (updated 2 Oct 2009)
    Information and Data Management (129 kb, PDF)
  • Chapter 11
    Data Quality Evaluation and Assessment (37 kb, PDF)
  • Chapter 12
    References (87 kb, PDF)
  • Chapter 13
    Glossary of Terms (83 kb, PDF)

Appendices:

  • Appendix 2-A
    Checklist for Review of a QAPP (34 kb, PDF)
  • Appendix 3-A
    Field Audit Checklist (173 kb, PDF)
  • Appendix 4-A
    FDEP and EPA Maximum Contaminant Levels for Drinking Waters (12 kb, PDF)
  • Appendix 4-B
    Criteria for Surface Water Quality Classifications (132 kb, PDF)
  • Appendix 5-A
    Electronic Data Deliverables Requirement for ADAPT CERP Projects (101 kb, PDF)
  • Appendix 7-A
    Soil, Sediment, and Porewater Sampling
    Procedures (339 kb, PDF)
  • Appendix 7-B
    Methods for In-situ Surveys and Physical
    Measurements (174 kb, PDF)
  • Appendix 7-C
    Ecological Laboratory Analyses and Assays (84 kb, PDF)
  • Appendix 9-B
    Common Remote Sensing Terminologies and Definitions (144 kb, PDF)
  • Appendix 9-C
    Additional Satellites and Sensors (23 kb, PDF)
  • Appendix 9-D
    Applicability of Remote Sensing Technologies (40 kb, PDF)
  • Appendix 9-E
    Example 1 - Remote Sensing Statement of Work (37 kb, PDF)
  • Appendix 9-F
    Example 2 - Remote Sensing Statement of Work (374 kb, PDF)
  • Appendix 9-G
    Example 3 - Remote Sensing Statement of Work (250 kb, PDF)
  • Appendix 9-H
    Example 4 - Remote Sensing Statement of Work (27 kb, PDF)
  • Appendix H
    Phytoplankton Methods Summary (280 kb, PDF)
  • Appendix I
    Periphyton Methods Summary (174 kb, PDF)
  • Appendix K
    Vegetation Methods Summary (1.9 mb, PDF)
  • Appendix L
    Invertebrates Method Summary (883 kb, PDF)
  • Appendix M
    Fish Methods Summary (831 kb, PDF)
  • Appendix M-1
    Collection, Handling, And Processing Of Tissue Samples For Contaminant Analysis (335 kb, PDF)
  • Appendix N
    Reptiles and Amphibians Methods Summary (182 kb, PDF)
  • Appendix O
    Birds Methods Summary (88 kb, PDF)

 

Related Links:

Contacts for this page:

 

Back to Top